Hercules Version 3: System Messages: TE - 1052/3270 Terminal Emulation
This page describes the terminal emulation messages for the Hercules S/370,
ESA/390, and z/Architecture emulator.
Messages
HHCTE001I Console connection thread started: tid=threadid,
pid=processid
- Meaning
- The thread that handles connection requests from console devices has
been started.
- Issued by
- console.c, function console_connection_handler
HHCTE002W Waiting for port port to become free
- Meaning
- The thread that handles connection requests from console devices
is waiting for the TCP port denoted by
port
to become
available for use.
- Action
- If this message persists, some other program has control of the TCP
port listed. Find out which one it is and terminate it.
- Issued by
- console.c, function console_connection_handler
HHCTE003I Waiting for console connection on port port
pid=num
- Meaning
- Hercules is ready to accept console connections on
port
port
.
- Issued by
- console.c, function console_connection_handler
HHCTE004I Console connection thread terminated
- Meaning
- The thread that handles connection requests from console devices has
been terminated.
- Issued by
- console.c, function console_connection_handler
HHCTE005E Cannot create console thread: reason
- Meaning
- The thread that handles connection requests from console devices could
not be started. The reason is shown as
reason
.
- Action
- Correct the reason listed and restart Hercules.
- Issued by
- console.c, function console_initialise
HHCTE006A Enter input for console device address
- Meaning
- The 1052 console device at
address
is waiting for input.
- Action
- Type the desired input for the console and press the ENTER key.
If you do not wish to get this message when input is requested,
define the console with the option
noprompt
.
- Issued by
- console.c, function constty_execute_ccw
HHCTE007I Device address closed by client ipaddr
- Meaning
- The client at IP address
ipaddr
that was
connected to the 3270 console at address address
has
closed the connection. The device is no longer available for use.
- Issued by
- console.c, function recv_3270_data
HHCTE008I Device address closed by client ipaddr
- Meaning
- The client at IP address
ipaddr
that was
connected to the 1052 console at address address
has
closed the connection. The device is no longer available for use.
- Issued by
- console.c, function recv_1052_data
HHCTE009I Client ipaddr connected to type device
address
- Meaning
- The client at IP address
ipaddr
has connected
to Hercules as a type
device and is now available at
address address
.
- Issued by
- console.c, function connect_client
HHCTE010E CNSLPORT statement invalid: statement
- Meaning
- The CNSLPORT statement in the hercules configuration file is invalid.
- Issued by
- console.c, function console_connection_handler
HHCTE011E Device devn: Invalid IP address: ipaddr
- Meaning
- The IP address
ipaddr
is invalid.
- Issued by
- console.c, function loc3270_init_handler or constty_init_handler.
HHCTE012E Device devn: Invalid mask value: ipmask
- Meaning
- The mask value
ipmask
is invalid.
- Issued by
- console.c, function loc3270_init_handler or constty_init_handler.
HHCTE013E Device devn: Extraneous argument(s): xxx...
- Meaning
- The argument
xxx
and any which follow it (if any)
was not recognized nor understood and are thus invalid.
- Issued by
- console.c, function loc3270_init_handler or constty_init_handler.
HHCTE014I type device devn disconnected.
- Meaning
- The client connected to device
devn
has
abruptly terminated the connection (ECONNRESET).
- Issued by
- console.c, function recv_3270_data
HHCTE017E Device devn: Duplicate SYSG console definition
- Meaning
- Device number
devn
has been defined as
an integrated 3270 (SYSG) console, but a SYSG console already
exists. Only one SYSG console can be defined per system.
- Issued by
- console.c, function loc3270_init_handler
If you have a question about Hercules, see the
Hercules Frequently-Asked Questions page.
Last updated $Date$ $Revision$